  • 【Technology】 Causes of circuit breaker heating or burning
    Updated 09/09/2020
    If there is no leakage and the line is tightened, the neutral line burns badly, then the neutral line return current is too large! For example, on the same working circuit, when installing wires, several live wires will be pulled to various devices, while the neutral wire only shares one. In the work...
    Tags: zero line
  • 【Technology】 Causes of current noise in the circuit breaker
    Updated 09/09/2020
    The contact is not in good contact. After the power failure, the incoming and outgoing wires must be tightened again. There may be a quality problem with the air switch itself. It is recommended that you replace it with a larger capacity air switch, and then be sure to plug in the grounding plug inst...
    Tags: air switchcurrent
  • 【Technology】 Advantages and disadvantages of vacuum circuit breakers
    Updated 09/09/2020
    Vacuum circuit breakers are mostly used in high-voltage switchgear, which refers to a circuit breaker that uses vacuum as an arc extinguishing and insulating medium to open and close current in a vacuum vessel. Since the advent of vacuum circuit breakers in the early 1960s, with the improvement of va...
    Tags: vacuum circuit breakerhigh voltage switch cabinet
  • 【Technology】 Selection of low-voltage circuit breakers and common fault handling methods
    Updated 09/09/2020
    The selection of low-voltage circuit breakers should pay attention to the following points. The rated current and rated voltage of the low-voltage circuit breaker should be greater than or equal to the normal working voltage and working current of the line and equipment. The limit making and breaking...
    Tags: low-voltage circuit breaker
  • 【Technology】 Selection principle of circuit breaker
    Updated 09/09/2020
    Low-voltage electrical appliances choose circuit breakers with different types of short-circuit breaking capacity to meet the needs of different line expected short-circuit currents (when I is in the same situation). The selection principle of circuit breaker is: 1. The short-circuit breaking capacit...
    Tags: household applianceslow-voltage electrical appliances
  • First
  • Prev
  • 30
  • 31
  • 32
  • Next
  • Last
  • Products
    ACB
    MCCB
    ATS
    MCB
    HMCB
    Blog
    Company
    Industry
    FAQs
    Technology
    About Us
    R&D Platform
    Quality Platform
    Manufacturing
    Address:No 658,Jinzhong Road,Changning District Shanghai China
    Tel:+86-021-33555507
    Email:[email protected]